Dowelmark
FDA recognised consensus standards, as an API and a feed

Declare the edition FDA recognises. Not the one it replaced.

Dowelmark tells regulatory teams and their AI agents whether FDA recognises a consensus standard edition on a given day, under which recognition number, and what replaced it, cited to the Federal Register list.

FDA's database moves first and the Federal Register follows, months later. Dowelmark reads both, replays every list since 2008, and answers for any date with the list, the citation and the data version an auditor will ask for.

List 066, applicable 24 Aug 2026
35new recognitions
28editions replaced
2withdrawn outright
1changed in place
recognition_status
// our biocompatibility report cites the 2018 edition
{"standard":"ISO 10993-1:2018"}
{
  "found": true,
  "recognized": false,
  "answer": "On 2026-11-29 ISO 10993-1 Fifth edition 2018-08 (2-258) is superseded: Recognition List 066 (2026-08-24) replaced it with ISO 10993-1 Sixth edition 2025-11 (2-313); FDA's database still listed it on 2026-11-10, so it is most likely inside its transition period (end date on the detail page).",
  "results": [
    {
      "recognitionNumber": "2-258",
      "citation": "ISO 10993-1 Fifth edition 2018-08",
      "status": "superseded",
      "until": "2026-08-24",
      "endedBy": {
        "list": "066",
        "frCitation": "91 FR 54715",
        "change": "Withdrawn and replaced with newer version."
      },
      "successors": [
        {
          "recognitionNumber": "2-313",
          "citation": "ISO 10993-1 Sixth edition 2025-11",
          "status": "recognized"
        }
      ],
      "transition": {
        "stillListedInDatabase": true
      }
    }
  ],
  "dataVersion": "2026-08-24.list066.db20261110"
}
Real output, run on 29 November 2026, trimmed to these fields and otherwise unchanged. Data version 2026-08-24.list066.db20261110.
A long, quiet testing laboratory with tall universal testing machines, technicians in lab coats seated at their consoles and a polished floor reflecting the windows

Every standard in a submission, a test plan or a supplier file names an edition. Dowelmark says whether FDA recognises that edition on the day that counts, and what to cite instead.

Photo: xing bowen, Unsplash
What changes for you

Three jobs that stop depending on someone checking FDA's database by hand.

Regulatory affairs lead

File with the edition FDA recognises on the filing date.

Ask about the day you submit, not the day you wrote the report. A replaced edition comes back as superseded, with its successor, the list that replaced it and whether FDA still lists the old one.

"We file on 15 December 2026 and our report cites ISO 10993-1:2018."On 2026-12-15 ISO 10993-1 Fifth edition 2018-08 (2-258) is superseded: Recognition List 066 (2026-08-24) replaced it with ISO 10993-1 Sixth edition 2025-11 (2-313); FDA's database still listed it on 2026-11-10, so it is most likely inside its transition period (end date on the detail page).recognition_status, date 2026-12-15, real answer

QMS and regulatory software

Keep your standards register current from a feed.

Poll once a night for what FDA added, replaced, withdrew or changed since your last sync, filtered to your customers' specialties, with nextCursor paging and a data version to store beside it.

"What changed for software standards since our sync on 20 February 2026?"4 rows, all in List 066: 13-106 replaced (Withdrawn and replaced with newer version); 13-142 modified (Transition period extended); 13-157 recognized; 13-158 recognized.changes_since, specialty software, real answer

Verification and test engineering

Check every standard a test plan cites, in one pass.

Hand the plan's list to an agent. Each edition comes back recognised, superseded or withdrawn, with extent and the date FDA entered it, before the lab books a single test.

"Our ventilator test plan cites ISO 80601-2-12:2020."On 2026-11-29 ISO 80601-2-12 Second edition 2020-02 (1-146) is superseded: Recognition List 063 (2025-03-20) replaced it with ISO 80601-2-12 Third edition 2023-11 (1-187); FDA's database still listed it on 2026-11-10, so it is most likely inside its transition period (end date on the detail page).recognition_status, real answer

The record

47 lists, September 2008 to August 2026.

Each column is one FDA Recognition List, placed on the day it applied and stacked by what it did. Quiet years, then a list that touches hundreds of rows. Whatever checks your standards has to survive both. Select a column to read the list.

2008201020122014201620182020202220242026
Recognised as new 1,222 Replaced by a newer edition 1,993 Withdrawn 520 Changed in place 1,594

Rows per list from the Federal Register notices, Lists 020 to 066, as parsed by Dowelmark. A replaced row also recognises its successor, which is counted under replaced here. Lists 001 to 019 used an older numbering and are held as references only.

The problem

Three gaps between what FDA knows and what your system can read.

None of them is a fault at FDA. Together they mean a register that checks standards against a copy of the list is usually behind, and cannot say by how much.

  1. 01

    The database leads, the list trails

    FDA enters recognitions in its database first and publishes them in the Federal Register later. All 63 recognitions in List 066 carry a date of entry of 25 May 2026: 91 days before the list applied.

    List 066, one batch of recognitions
    91 days
    97 days and counting
    25 May 2026Date of entry in FDA's database
    24 Aug 2026List 066 applies
    29 Nov 2026Still the newest list

    Dates of entry from FDA's database as read on 10 November 2026. Asked about a day in between, Dowelmark answers with its own status for the gap: in_database_pending_list.

  2. 02

    Transition dates live on detail pages

    A list says an edition was "withdrawn and replaced with newer version". How long FDA still accepts declarations to the old one is written on a detail page, one per standard. Dowelmark already says whether a replaced edition is still in FDA's database: 230 are, most likely inside a transition. The end dates themselves are not held yet, and no answer guesses them.

  3. 03

    The bulk export is closed to robots

    FDA's robots file disallows the spreadsheet export and asks crawlers to visit only between 23:00 and 05:00 US Eastern time, one request every 30 seconds. Polling it from your product is not an option, so Dowelmark reads the results page inside that window and serves the copy, dated.

How it works

From numbered notices and one results page to one history per recognition number.

68

Federal Register notices

Every FDA notice titled Modifications to the List of Recognized Standards, from the Federal Register API.

1,738

Database recognitions

FDA's full results page, read on 10 Nov 2026 inside its visiting hours: date of entry, extent and current citation.

47

Lists replayed in order

Lists 020 to 066, oldest first, so each change lands on the state the one before it left.

3,953

Recognition histories

1,480 in force in both sources, 239 ended in the lists but still listed, 34 unconfirmed.

5

Tools, one schema

Over MCP, HTTP and a CLI. Every result names its list, Federal Register citation and data version.

Not yet in the feed

Transition end dates. FDA writes them on one detail page per recognition, read only inside the visiting hours at one request every 30 seconds, so the backfill takes several nights. Until then every answer about a replaced edition says whether FDA still lists it and links its detail page. How it works, in full.

The feed

Poll it like a changelog.

Ask for everything since your last sync, filtered to the specialties your customers work in. Page with nextCursor. Store the data version with what you show. Or subscribe to the RSS feed, one item per list.

Software specialty, since List 066
// changes_since
{"since":"2026-08-24","specialty":"Software","limit":2}

{
  "total": 4,
  "changes": [
    {
      "list": "066",
      "recognitionNumber": "13-106",
      "citation": "IEEE Std 11073-10207-2017",
      "kind": "replaced",
      "change": "Withdrawn and replaced with newer version.",
      "replacedBy": [
        "13-157"
      ]
    },
    {
      "list": "066",
      "recognitionNumber": "13-142",
      "citation": "FIRST CVSS 3.1 Common Vulnerability Scoring System version 3.1",
      "kind": "modified",
      "change": "Transition period extended."
    }
  ],
  "nextCursor": "2"
}
One list, as a record
// recognition_list
{"list":"066","limit":1}

{
  "listInfo": {
    "list": "066",
    "frDocument": "2026-17229",
    "frCitation": "91 FR 54715",
    "effective": "2026-08-24",
    "docket": "FDA-2004-N-0451",
    "counts": {
      "replaced": 28,
      "withdrawn": 2,
      "modified": 1,
      "recognized": 35
    }
  },
  "total": 94,
  "nextCursor": "1"
}
Sources and proof

Public domain at the source, cited in every row.

Federal Register
68 notices, Lists 001 to 066, fetched through the Federal Register API with an honest user agent and robots.txt honoured. Republication allowed without restriction (1 CFR 2.6).
FDA database
The full results page, read on 10 November 2026 inside its visiting hours: 1,738 recognitions, 1,584 complete and 154 partial. The spreadsheet export, closed to robots, is never used.
Checked before it ships
137 oracle vectors taken from the Federal Register documents and FDA's database, plus 56 tests and 87 end to end checks across MCP, HTTP and the CLI. A refresh replaces the data only when the new build passes them.
Honest about gaps
34 recognitions are in force by the lists but missing from FDA's database; they come back as unconfirmed, never as recognised. See where the sources disagree.
Deterministic
No language model writes or changes any answer: the tools are deterministic code over FDA's own records. The same question gets the same answer on every surface.
Never served
Scope or abstract text from ISO, IEC, ASTM or any other standards body, and the text of any standard. Titles appear as FDA lists them; the official text published by the standards body prevails.

Source: Food and Drug Administration, Modifications to the List of Recognized Standards, Recognition Lists published in the Federal Register (federalregister.gov), a US government work. Replayed into recognition histories by Dowelmark. Sources and freshness.

Pricing

Priced per call volume, not per seat.

Free
EUR 0
20 calls a day
No sign-up. Try the feed against your own standards register, from a browser or an agent.
Pro
EUR 29a month
2,000 calls a month
One regulatory affairs specialist or consultant checking the standards in their own submissions, alone or from one agent.
Team
EUR 99a month
10,000 calls a month
A regulatory or quality team checking every standard in its submissions, test plans and supplier files, and polling for new lists.
Platform
EUR 299a month
60,000 calls a month
A regulatory consultancy or QMS software vendor that checks standards for many clients or embeds the lookup in its own product.

Prices exclude VAT. Business customers only. Paid plans open once the trading details in the imprint are filled; until then everything runs on the free tier.

Connect

One MCP server. One HTTP endpoint per tool.

Claude

In Claude, open Settings, Connectors, Add custom connector, and paste the URL. In Claude Code:

shell
claude mcp add --transport http dowelmark https://dowelmark.bulkhead.solutions/mcp

Cursor

Add to .cursor/mcp.json:

mcp.json
{
  "mcpServers": {
    "dowelmark": {
      "url": "https://dowelmark.bulkhead.solutions/mcp"
    }
  }
}

ChatGPT

In ChatGPT with developer mode on, create a connector with this MCP server URL:

address
https://dowelmark.bulkhead.solutions/mcp

Plain HTTP

Every tool is a POST with a JSON body. No key needed for 20 calls a day:

shell
curl -X POST https://dowelmark.bulkhead.solutions/v1/tools/recognition_status \
  -H 'content-type: application/json' \
  -d '{"standard":"ISO 10993-1:2018"}'

Private preview: dowelmark.bulkhead.solutions is the planned address and opens after registration. The same five tools run today from the command line and as a local MCP server.

From the blog

Automated and unreviewed. Dowelmark reads official sources automatically and no person checks each answer. Data can be incomplete, late or wrong. Always verify against the official source linked with every answer before you act. Not legal, regulatory, tax, customs or medical advice. FDA's database and its Federal Register notices decide what FDA recognises, and the official text published by the standards body prevails for the content of any standard. Dowelmark is independent of FDA and of every standards body.