NEMA MS 5-2003 Determination of Slice Thickness in Diagnostic Magnetic

NEMA MS 5-2003 Determination of Slice Thickness in Diagnostic Magnetic Resonance Imaging

Superseded

On 2026-11-29 NEMA MS 5-2003 Determination of Slice Thickness in Diagnostic Magnetic (12-125) is superseded: Recognition List 028 (2012-03-16) replaced it with NEMA MS 5-2010, Determination of Slice Thickness in Diagnostic Imaging (12-231); FDA's database no longer lists it.

Answer from recognition_status on 29 November 2026, data version 2026-08-24.list066.db20261110.

Superseded is not refused. FDA usually still accepts declarations of conformity to a replaced edition for a transition period, which it states on the standard's detail page in its database, not in the Federal Register. No longer listed in FDA's database on 2026-11-10, so any transition period has most likely ended. Search FDA's database.
Status on 29 Nov 2026
Superseded
Recognition number
12-125
Specialty
Radiology
Extent
Not listed in FDA's database on 2026-11-10, so no extent is given.
Recognised since
Before 9 Sep 2008 (earlier than the lists replayed row by row)
Ended
16 Mar 2012, List 028
FDA date of entry
Not listed on 10 Nov 2026
In FDA's database
Not listed on 10 Nov 2026
Replaced by
12-231, NEMA MS 5-2010, Determination of Slice Thickness in Diagnostic Imaging

Every edition under this line

  1. 12-125 NEMA MS 5-2003 Determination of Slice Thickness in Diagnostic MagneticSuperseded, recognised before 9 Sep 2008 to 16 Mar 2012, this page
  2. 12-231 NEMA MS 5-2010, Determination of Slice Thickness in Diagnostic ImagingSuperseded, from 16 Mar 2012 to 14 Mar 2019
  3. 12-322 NEMA MS 5-2018Recognised, from 14 Mar 2019

What each Federal Register list did

ListApplicableChangeFDA's own wordsCitation
List 0209 Sep 2008Changed in placeRelevant guidance and Contact person73 FR 52358
List 02816 Mar 2012Replaced, by 12-231Withdrawn and replaced with newer version.77 FR 15765

Sources

Automated and unreviewed. Dowelmark reads official sources automatically and no person checks each answer. Data can be incomplete, late or wrong. Always verify against the official source linked with every answer before you act. Not legal, regulatory, tax, customs or medical advice. FDA's database and its Federal Register notices decide what FDA recognises, and the official text published by the standards body prevails for the content of any standard. Dowelmark is independent of FDA and of every standards body.