IEC 60601-2-1:2014

IEC 60601-2-1 Edition 3.1 2014-07 Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV

Superseded

On 2026-11-29 IEC 60601-2-1 Edition 3.1 2014-07 (12-285) is superseded: Recognition List 056 (2021-12-09) replaced it with IEC 60601-2-1 Edition 4.0 2020-10 (12-338); FDA's database no longer lists it.

Answer from recognition_status on 29 November 2026, data version 2026-08-24.list066.db20261110.

Superseded is not refused. FDA usually still accepts declarations of conformity to a replaced edition for a transition period, which it states on the standard's detail page in its database, not in the Federal Register. No longer listed in FDA's database on 2026-11-10, so any transition period has most likely ended. Search FDA's database.
Status on 29 Nov 2026
Superseded
Recognition number
12-285
Specialty
Radiology
Extent
Not listed in FDA's database on 2026-11-10, so no extent is given.
Recognised since
27 Jan 2015, List 038
Ended
9 Dec 2021, List 056
FDA date of entry
Not listed on 10 Nov 2026
In FDA's database
Not listed on 10 Nov 2026
Replaced by
12-338, IEC 60601-2-1 Edition 4.0 2020-10
Replaces
12-206, IEC 60601-2-1 Edition 3.0 2009-10

Every edition under this line

  1. 12-152 IEC 60601-2-1 Second editionSuperseded, recognised before 10 Jun 2010 to 10 Jun 2010
  2. 12-206 IEC 60601-2-1 Edition 3.0 2009-10Superseded, from 10 Jun 2010 to 27 Jan 2015
  3. 12-285 IEC 60601-2-1 Edition 3.1 2014-07Superseded, from 27 Jan 2015 to 9 Dec 2021, this page
  4. 12-338 IEC 60601-2-1 Edition 4.0 2020-10Recognised, from 9 Dec 2021

What each Federal Register list did

ListApplicableChangeFDA's own wordsCitation
List 03827 Jan 2015Recognised, replacing 12-206No change text: a row in the list's table of new entries80 FR 4274
List 0569 Dec 2021Replaced, by 12-338Withdrawn and replaced with newer version.86 FR 70132

Sources

Automated and unreviewed. Dowelmark reads official sources automatically and no person checks each answer. Data can be incomplete, late or wrong. Always verify against the official source linked with every answer before you act. Not legal, regulatory, tax, customs or medical advice. FDA's database and its Federal Register notices decide what FDA recognises, and the official text published by the standards body prevails for the content of any standard. Dowelmark is independent of FDA and of every standards body.