Dowelmark
FDA recognition 6-325 ยท General Hospital/General Plastic Surgery

IEC 60601-2-21:2009

IEC 60601-2-21 Edition 2.0 2009-02 Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers [Including: Technical corrigendum 1 (2013)]

Superseded

On 2026-11-29 IEC 60601-2-21 Edition 2.0 2009-02 (6-325) is superseded: Recognition List 047 (2017-08-21) replaced it with IEC 60601-2-21 Edition 2.1 2016-04 CONSOLIDATED VERSION (6-388); FDA's database no longer lists it.

Answer from recognition_status on 29 November 2026, data version 2026-08-24.list066.db20261110.

Superseded is not refused. FDA usually still accepts declarations of conformity to a replaced edition for a transition period, which it states on the standard's detail page in its database, not in the Federal Register. No longer listed in FDA's database on 2026-11-10, so any transition period has most likely ended. Search FDA's database.
Status on 29 Nov 2026
Superseded
Recognition number
6-325
Specialty
General Hospital/General Plastic Surgery
Extent
Not listed in FDA's database on 2026-11-10, so no extent is given.
Recognised since
9 Jul 2014, List 036
Ended
21 Aug 2017, List 047
FDA date of entry
Not listed on 10 Nov 2026
In FDA's database
Not listed on 10 Nov 2026
Replaced by
6-388, IEC 60601-2-21 Edition 2.1 2016-04 CONSOLIDATED VERSION
Replaces
6-300, IEC 60601-2-21 Edition 2.0 2009-02

Every edition under this line

  1. 6-9 IEC 60601-2-21 First edition 1994-02Superseded, recognised before 10 Jun 2010 to 10 Jun 2010
  2. 6-300 IEC 60601-2-21 Edition 2.0 2009-02Superseded, from 6 Aug 2013 to 9 Jul 2014
  3. 6-325 IEC 60601-2-21 Edition 2.0 2009-02Superseded, from 9 Jul 2014 to 21 Aug 2017, this page
  4. 6-388 IEC 60601-2-21 Edition 2.1 2016-04 CONSOLIDATED VERSIONSuperseded, from 21 Aug 2017 to 9 Dec 2021
  5. 6-463 IEC 60601-2-21 Edition 3.0 2020-09Recognised, from 9 Dec 2021

What each Federal Register list did

ListApplicableChangeFDA's own wordsCitation
List 0369 Jul 2014Recognised, replacing 6-300No change text: a row in the list's table of new entries79 FR 38910
List 04721 Aug 2017Replaced, by 6-388Withdrawn and replaced with newer version including amendment.82 FR 39591

Sources

Automated and unreviewed. Dowelmark reads official sources automatically and no person checks each answer. Data can be incomplete, late or wrong. Always verify against the official source linked with every answer before you act. Not legal, regulatory, tax, customs or medical advice. FDA's database and its Federal Register notices decide what FDA recognises, and the official text published by the standards body prevails for the content of any standard. Dowelmark is independent of FDA and of every standards body.